Customer Service Quick Delivery For Professionals and privates
Rating
0 0

Commenting is not enabled on this course.

4. E.C. Declaration of Conformity The manufacturer or its legal representative supplier in the European Community: Honeywell Safety Products Europe Declares that the Personal Protective Equipment described here after conforms to the provisions of the European Council Directive 89/686/CEE: Designation: Clearflow 3 on portable stand with 2 CEJN outlets Reference: 1763904 Standard(s): This PPE is the object of the below EC examination certificate n°: Delivered by: Drawn up in , on the 28/07/2017 By : Division : Respiratory Protection Zl Paris Nord II 33, rue des Vanesses BP 50288 95958 Roissy CDG France Tel: +33 (0) 49 90 79 79 Fax: +33 (0)1 49 90 79 80 www.honeywellsafety.com

2. Feature Easy use and easy maintenance Benefit New one piece compact design Feature Provide security to worker Benefit Its diffenrential pressure indicator doesn't give bad value judgement Compressed Airline Infiltration System Floor Model on portable stand with 2 CEJN outlets Filter - Coalescing filter : 1000 hours with a filtration at 99,97% to 0,01 micron - Charcoal filter : 1000 hours (or when odours are detected inside respiratory device) Filters are compliant with ISO 8573 -1 : Compressed Air - Part 1: Pollutants and purity classes which specifies the quality class of compressed air for the presence of particles, water or oil, irrespective of the mode of generation of the compressed air Supply Pressure 8 bar maximum Airflow Rate 1600L/mn Material Filters with Aluminium body Regulators with some plastic and brass components Polycarbonate bowl Nitrile seals ABS cover Technical Description E.C. Declaration of Conformity Certifications Product Sheet CL3 English http://www.honeywellsafety.com/supplementary/documents_and_downloads/respiratory_protection /sar/4294973354/1033.aspx Literature & Documents User Manual User Manual Clearflow 3 Additional Information Storage Information Store the filtration unit in its original packaging so that it is protected from sun and dust Do not expose to direct sunlight Maintenance 1763904 - Compressed Airline Filtration Unit Clearflow 3 Portable stand Page 2 Of 3 © Honeywell International Inc.

6. Standards The Clearflow system is not subject to the PPE directive. Product Use User’s instructions for installation Wall-Mounted system : • Attach the wall-mounted on a flat wall near the work station. • Keep enough space under the unit filtration to allow for removal of the covers and filters changes (40 cm). • Connect the compressed air from factory to the isolation valve (1) with a male ½” BSP. • Connect the respirator provided to the output (9) with a inner diameter hose of 14mm. Portable stand system : • The portable station can be positioned freely within the workplace. • Connect the isolation valve (1) to the compressed air network using a male connector ½” BSP. • The hose connecting the system to the network of compressed air should have an internal diameter of 14mm. • Connect the respirator supplied to the output connections (9) with the specified hoses. Controls before use • Carefully open the air inlet valve (1) slowly to prevent air too surges. Otherwise it could cause incorrect indications on the clogging indicator (6). • The air pressure in the system is indicated by the pressure gauge (8) and can be adjusted using the valve regulator (7). • When the air pressure is satisfactory, push the valve down to lock setting. • The pressure must be adjusted taking into account the user manual of the respiratory equipment used up to 8 bar (102psi). Cleaning The compressor must be inspected and the filter bowls must be purged regularly. Limitations of use Clearflow 3 filter systems do not remove CO or CO2. Disposal Filters must be disposed in accordance with the local waste disposal regulations. Maintenance For details please refer to the user manual. n umbers Part n umber Description N°1 17 633 41 Isolating Valve N°2 17 639 23 Wall mounting bracket for regulator N°3 17 639 22 Ring for regulator mounting bracket N°4 17 639 26 Body connector (with 2 O-ring gaskets) N°5 17 639 25 Body connector with wall support (with 2 O-ring gaskets) 17 639 24 5 O-ring gaskets N°6 17 639 21 Differential pressure indicator (available as a service/repair kit) N°7 17 639 14 Differential pressure indicator (available as a service/repair kit) N°8 10 017 07 Pressure gauge N°9 10 017 22 Quick release outlet socket (CEJN for use with Airvisor) 17 634 20 Quick release outlet socket (RBE6) 17 634 22 Quick release outlet socket (AQR6) 17 639 20 Quick release outlet socket (double action for use with Airvisor 2 DHC) N°10 17 639 28 Replacement coalescing filter stage (complete, supplied with in let adaptor) 17 639 08 Coalescing filter element N°11 17 639 16 Replacement absorber filter stage 17 639 07 Absorber filter element N°12 17 639 27 Filter element cover (with manual drain) N°13 10 170 50 Stand (complete with fixing bolts) 10 050 60 Doubling kit for use with Airvisor (“Y” piece + one CEJN connec tor) 17 633 33 Doubling kit AQR (“Y” piece + one AQR 06 connector) 17 633 35 Doubling kit RBE (“Y” piece + one RBE 06 connector) 17 639 29 Doubling kit double action (“Y” piece + one double action connector) Honeywell Safety Products Sperian Protection UK LTD Unit 3 Elmwood - Chineham Park - Basingstoke - RG24 8WG - United Kingdom Phone: +44 (0) 1256 693 200 - Fax: +44 (0) 1256 693 300 Email: info-uk.hsp@honeywell.com

3. Care Instructions Controls before use Carefully open the air inlet valve (1) slowly to prevent air too surges. Otherwise it could cause incorrect indications on the clogging indicator (6) The air pressure in the system is indicated by the pressure gauge (8) and can be adjusted using the valve regulator (7) When the air pressure is satisfactory, push the valve down to lock setting. The pressure must be adjusted taking into account the user manual of the respiratory equipment used up to 8 bar (102psi) Limitations of use Clearflow 3 filter systems do not remove CO or CO2 Disposal Filters must be disposed in accordance with the local waste disposal regulations. Accessories Part # Description 1001726 Blueline hose, length 3.5m with quick release couplings 1001727 Blueline hose, length 7.5m with quick release couplings 1004716 Blueline hose, length 10m with quick release couplings 1760087 Hose 9 x 16, length 10m with RBE6 connection 1764002 Drum with 60m of hose 9 x 16 and RBE6 connection Spare Parts Below the link to download the file "Technical View with list of spare parts" Spare Parts File Technical View Clearflow 3 with list of spare parts Parts & Accessories EAN Code 0000017639040 Packaging Specs Individual Box 15x35x27 Unit of Measure cm Quantity per Box/Pack/Case 1 Country of Origin FR Packaging © Honeywell International Inc. 1763904 - Compressed Airline Filtration Unit Clearflow 3 Portable stand Page 3 Of 3 © Honeywell International Inc.

1. Europe / Africa Automotive and Part Manufacturer Chemical Industries Energy or Electricity General Industry Laboratory Petro-chemical Reference Number 1763904 Product Type Respiratory Protection Range Supplied Air Respirators Line Compressed airline filtration systems Brand Honeywell Industry Product Use Depend of face-piece used with it. Typical usage are : Handling or maintenance in Oil & Gas industry environment Handling or maintenance in Chemical industry environment Painting or varnish in automotive industry Work close to viruses or bacteria inside laboratory Overview Feature High filtration capacity Benefit Due to : - high flow system (no flow change when connecting auxiliary tools) - High efficiency of coalescing filter - High capacity of absorber carbon filter Features & Benefits Clearflow 3 on portable stand with 2 CEJN outlets PRODUCT NUMBER: 1763904 The CLEARFLOW 3 compressed airline filtration unit has been designed to deliver high quality breathable air to a range of respiratory devices. Compressed air factory network contained particles and traces of oil and water. The CLEARFLOW 3 remove these trough its coalescing filter. Where the removal of oil vapour and odour is necessary the use of carbon absorber filter is required. The CLEARFLOW 3 can supply breathable for up to 4 workers using supplied aur respirators, or up to 2 operators using respirators in combination with auxiliary tools such as hand held paint spraying equipment. Page 1 Of 3 © Honeywell International Inc.

5. Product Sheet – Filtration unit CLEARFLOW 3 Fi L t RA ti O n Unit Description The Clearflow 3 compressed air filtration unit has been designed to deliver high quality breathable air to a range of respiratory devices. Compressed air factory network contained particles and traces of oil and water, Clearflow 3 removes these through its coalescing filter. Where the removal of oil vapour and odour is necessary the use of a carbon absorber filter is required. The Clearflow 3 range is available in wall mounted and portable stand versions. The Clearflow 3 can supply breathable air for up to four operators using supplied air respirators, or up to two operators using respirators in combination with auxiliary tools such as hand held paint spraying equipment. Benefits • High filtration capacity due to high flow system (no flow change when connecting auxiliary tools), high efficiency coalescing filter and high capacity carbon filter. • New one piece compact design which offers easy use and easy maintenance. • Provides security to worker with its differential pressure indicator (no bad value judgment). • Can be used for up to 4 workers. • The Clearflow 3 system is available in various configurations: dif ferents outlets, wall-mounted or stand, used with PPE Applications (Depending on face-piece used with it) Typical usage are : • Handling or maintenance in Oil & Gas industry environment. • Handling or maintenance in Chemical industry environment. • Painting or varnish in automotive industry. • Work close to viruses or bacteria inside laboratory. WALL-MOU nt ED PAR t #: 17 639 03 CL3 with 2 CEJN outlets Airvisor 17 639 05 CL3 with 2 RBE 06 Outlets 17 639 11 CL3 with 2 double action outlets 17 639 09 CL3 with 2 free outlets POR t ABLE PAR t #: 17 639 04 CL3 with 2 CEJN outlets Airvisor 17 639 06 CL3 with 2 RBE 06 outlets 17 639 12 CL3 with 2 double action outlets 17 639 10 CL3 with 2 free outlets Characteristics • Material : Aluminium bodied filters, regulators with some plastic and brass components. Supply with CEJN, RBE, Double action or free Outlets but without Quick release connectors. • t echnical i nformation : Coalescing filter: 1000 hours (or when colour change) filtration 99,97% to 0,01 micro Charcoalfilter: 1000 hours (or when ordours are detected inside respiratory device) Air flow: 1600l/mn maximum. Air pressure: 8 bar maximum (102 psi). • Storage conditions : May be used by up to 4 operators with respiratory face pieces only or by up to 2 operators with face pieces and pneumatic tools. Portable version Wall-mounted version Net Weight 4,45 kg 1,90 kg Product dimensions 33,5 x 38,5 x 34 cm 33 x 24 x 9 cm Packaging dimensions Individually packed 46 x 45 x 48 cm 35 x 27 x 15 cm

Safety For Everybody

Stay safely updated with the latest news and knowledge within PPE and work environments