Documentation
Completed
Ose_directory e-shot
4110 Views •Check Line II maintenance manual
5118 Views •Chemsplash Pro WD40 Test
4578 Views •ergonomics 2006
5103 Views •Ose_directory Suspension harness
4392 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
5556 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
5226 Views •VISOR Installation steps
5472 Views •Disinfection Products with effect on Corona Virus 2019 Ncov
4645 Views •Hearing protection 3M
4053 Views •Statistics for work in 2014
4799 Views •LOTO_GuideBook_Europe_English
4889 Views •Remote Area Lighting System
3494 Views •Isol8 - The Ultimate Absorbent for Spills
3562 Views •Work Magazine - November 2012
3971 Views •KEE_DOME_MINI
3919 Views •TDS Speedglas 9100
4114 Views •The Pocket Book of Lean Visuals
4230 Views •Instructional videos Sign holder
3392 Views •PREMARK installation manual
4473 Views •D-S CSR Handbook
20792 Views •Find glove size - size guide for gloves
13729 Views •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
11696 Views •3M jupiter manual
9273 Views •83735-00000A Safety Data Sheet
8750 Views •D S 70th Us brochure
8644 Views •9100 Manual
8022 Views •Explanation of the new EN ISO 374 standard chemicals
7200 Views •LA600 UI A3 26 LANGUAGES 22 08 2019 598
7010 Views •Fall Protection flyer
6999 Views •EN 388 new labels explanation
6954 Views •3M TR 300 PAPR training video
6521 Views •How to calibrate a 3M Jupiter air flow unit
6519 Views •TR-300 User manual
6056 Views •GuardianChemicalReport
5910 Views •3M Filterguide_DK
5789 Views •Selection Guide respirator
5587 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
5556 Views •VARMEX 2000 Benefits
5540 Views •VISOR Installation steps
5472 Views •Honeywell_Clearflow_3_Brochure
Commenting is not enabled on this course.
1. CLEARFLOW 3 Construction Automotive C O mp RE ss E d Ai RL in E Fi L t RA ti O n s yst E m CLEARFLOW 3 Filtration unit t he CLEARFLOW 3 compressed air filter range has been developed to deliver high quality breathable air to a range of respiratory devices. Air is taken from the factory compressed air system, bulk oil and water are removed by the coalescing filter. Where the removal of oil vapour and odour is necessary the use of a carbon adsorber filter is required. t he Cleaflow 3 range is available in wall mounted and portable stand versions. Laboratory & p harmaceutical
2. The CLEARFLOW 3 is a compressed airline filtration system. The CLEARFLOW 3 is able to supply breathable air for up to four operators using supplied air respirators, or up to two operators using respirators in combination with auxiliary tools such as hand held paint spraying equipment. Its one-piece body design offers ease of use, no small or easily lost parts and robustness P ROTECTIO n • The CLEARFLOW 3 is equipped with: - High flow system providing more flow - High efficiency coalescing filter - High capacity adsorber carbon filter • This system will ensure safety against a broad range of hazards. i t ensure protection against solid and submicron particles, liquids contaminants and liquid aerosols. S EC u RIT y • The CLEARFLOW 3 has a pop up indicator which tells the user when it is time to change the filter. t here is no risk of bad value judgment. • It is possible to fully lock down the system so that the flow can not be changed or closed off by another worker. E AS y OF u SE • No tools are required to replace internal filter elements. • Adaptability to work environnements thanks to portable stand version or wall-mounted version. • The systems can be used to supply air to a variety of Honeywell respiratory equipment. SPECIFICATIONS Gross weight 2,2 kg for wall-mounted / 5 kg for portable stand Net weight 1,9 kg for wall-mounted / 4,45 kg for portable stand Product dimensions 33 x 24 x 9 cm (wall-mounted) / 33,5 x 38,5 x 34 cm (portable stand) Packaging dimensions (individual packed) 35 x 27 x 15 cm (wall-mounted) / 46 x 45 x 48 cm for (portable stand) Materials Aluminium body, plastic components (polycarbonate bowl, nitrile seals, ABS cover) and some brass components Standard Clearflow 3 systems are not items of Personal Protective Equipment (PPE) Filters are compliant with ISO 8573 -1 (Compressed Air - Part 1: Pollutants and purity classes) which specifies the quality class of compressed air for the presence of particles, water or oil, irrespective of the mode of generation of the compressed air Best suited for use in - With Airvisor visors: Intensives works in dusty environment, preparation of powders or non aggressive handling liquids with risks of splashing, painting and acrylic varnish inside cabin - With MC95 supplied air with mask: Heavy duty maintenance in chemical and oil & gas industry environment, work close to viruses or bacteria in laboratory environment Components - Coalescing filter element : 1000 hours services – 0,01 micron - Adsorber filter element : 1000 hours services – 0,008 ppm - Compressor : Up to 10 bar - Air Flow : up to 1600l/mn (depending upon user’s compressor and the limitation imposed by his compressed air system/network) ORDERING INFORMATION PART NUMBER CLEARFLOW 3 wall-mounted with 2 CEJN outlets for Airvisor 17 639 03 CLEARFLOW 3 on portable stand with 2 CEJN outlets for Airvisor 17 639 04 CLEARFLOW 3 wall-mounted with 2 RBE Outlets 17 639 05 CLEARFLOW 3 on portable stand with 2 RBE 06 outlets 17 639 06 CLEARFLOW 3 wall-mounted with 2 double action outlets 17 639 11 CLEARFLOW 3 on portable stand with 2 double action outlets 17 639 12 CLEARFLOW 3 wall-mounted with 2 free outlets 17 639 09 CLEARFLOW 3 on portable stand with 2 free outlets 17 639 10 CLEARFLOW 3 d OC3238 February 2013 © 2013 Honeywell International Inc. H O n E y WELL S AFET y P RO du CTS SPERIA n PROTECTIO n ( u K) LIMITE d Unit 3 Elmwood, Chineham p ark, Basingstoke, RG24 8WG Phone: +44 (0) 1256 693 200 - Fax: +44 (0) 1256 693 300 E-mail : info-uk.hsp@honeywell.com www.honeywellsafety.com H O n E y WELL S AFET y P RO du CTS Eu ROPE SAS i mmeuble Edison p aris n ord 2 - 33 rue des Vanesses CS 55288 Villepinte - 95958 Roissy CDG Cedex - France Tel : +33 (0)1 49 90 79 79 - Fax : +33 (0)1 49 90 71 04 Email: info-export.hsp@honeywell.com Lead them to safety — Build an enduring culture of safety where employees make safe choices on their own: http://honeywellsafety.com
Share This Content
Share Link
Share on Social Media
Share by Email
Please login to share this Document by email.