Documentation
Completed
Ose_directory e-shot
4263 Views •Check Line II maintenance manual
5347 Views •Chemsplash Pro WD40 Test
4726 Views •ergonomics 2006
5280 Views •Ose_directory Suspension harness
4545 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
5890 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
5394 Views •VISOR Installation steps
5653 Views •Disinfection Products with effect on Corona Virus 2019 Ncov
4836 Views •Hearing protection 3M
4189 Views •Statistics for work in 2014
5014 Views •LOTO_GuideBook_Europe_English
5080 Views •Remote Area Lighting System
3646 Views •Isol8 - The Ultimate Absorbent for Spills
3724 Views •Work Magazine - November 2012
4156 Views •KEE_DOME_MINI
4111 Views •TDS Speedglas 9100
4271 Views •The Pocket Book of Lean Visuals
4443 Views •Instructional videos Sign holder
3598 Views •PREMARK installation manual
4724 Views •D-S CSR Handbook
21056 Views •Find glove size - size guide for gloves
14012 Views •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
12684 Views •3M jupiter manual
9546 Views •83735-00000A Safety Data Sheet
8987 Views •D S 70th Us brochure
8967 Views •9100 Manual
8275 Views •Explanation of the new EN ISO 374 standard chemicals
7409 Views •Fall Protection flyer
7218 Views •LA600 UI A3 26 LANGUAGES 22 08 2019 598
7184 Views •EN 388 new labels explanation
7150 Views •3M TR 300 PAPR training video
6843 Views •How to calibrate a 3M Jupiter air flow unit
6699 Views •TR-300 User manual
6303 Views •GuardianChemicalReport
6154 Views •3M Filterguide_DK
6130 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
5890 Views •Selection Guide respirator
5751 Views •VARMEX 2000 Benefits
5743 Views •VISOR Installation steps
5653 Views •Q7947A Revision 0 EN352-10
Sikkerhed for alle
Indtast venligst din e-mail for at downloade denne fil
*Ved tilmelding accepterer du at modtage markedsføringsmailsCommenting is not enabled on this course.
2. Page 2 of 2 Table 2. Mean in ear noise levels using IEC 60268 - 1:1985 noise IEC 60268 - 1:1985 (dB FS) Mean (dBA) SD √Sum of squares Mean + √SS (dBA) - 35 66.3 5.0 5.8 72.1 - 30 69.4 3.2 4.4 73.8 - 25 71.8 0.7 3.1 74.9 - 20 72.5 0.2 3.0 75.5 - 15 72.5 0.2 3.0 75.5 - 10 72.5 0.2 3.0 75.5 Michael & Associates is accredited by the National Institute of Standards and Technology (NIST) National Laboratory Accreditation Program (NVLAP) for tests performed according to ANSI S3.19 - 1974, ANSI S12.6 - 2016, AS/NZ S1270:2002 and EN352 parts 1 - 10. These accreditation criteria encompass the requirements of international standard ISO 17025. This report may only be reproduced or transmitted electronically in its entirety. This report shall not be used to claim produc t approval, certification or endorsement by NIST, NVLAP or by any agency of the U.S. Government. All measurement equipment are calibrated with instrumentation traceable to the NIST. Accreditation documentation can be viewed at www.michaelassociates.com/data/documents/NVLAP - 2023.pdf . Kevin Michael, Ph.D. President R² = 0.7873 50 55 60 65 70 75 80 85 -40 -30 -20 -10 0 dBA IEC 60268 - 1:1985 ( dB FS) Bluetooth transmission linearity check and visual reference to 82 dBA threshold limit Mean + √SS (dBA) Exposure Threshold
1. Page 1 of 2 Test Report ID: Q 7 94 7 A Revision 0 Opsmen Tech Co., Ltd. Room 601, Building A, No.94 Liwan Road, Liwan District, Guangzhou, China Date of report: 1/ 3 1 /2 3 Date of sample receipt: 1 1 / 22 /22 Dates of testing: 1/ 30 /2 3 Technician: Sandar Bregg Table 1. Test Result Standard Maximum Output & usage time EN352 - 10 :2020 The maximum output level of 7 5.5 dBA was less than 82 dBA , the usage time is >8 hours Acoustic testing was performed on M 20 /M 2 0 T electr onic earplugs according to EN352 - 10 :2020 for Bluetooth transmission ( Test ID Q7 94 7 A ). For the EN352 - 10 :2020 testing, a G.R.A.S. 45CB fixture was tested on each of the four samples twice for a total of eight measurements or 16 ears. The mean, standard deviation, and square root of the standard deviation’s sum of squares at each of the noise levels were calculated and presented in Table 1. Individual data is presented in the appendix. Noise levels tested ranged between - 35 dB FS to - 10 d B FS in 5 dB increments. For all tests, t he test signal IEC 60268 - 1:1985 noise and volume controls were set to maximum . The maximum output level of 7 5 . 5 dBA did not exceed the 82 dBA threshold limit and passed this test. 2766 W. College Ave Suite 1 State Colleg e, PA 16801 814 - 234 - 7042 phone 814 - 235 - 1381 fax Email: Kevin@michaelassociates.com URL: www.michaelassociates.com Figure 1 . M 20 /M 2 0 T electr onic earplugs
3. APPENDIX 1 OF 1 Table 3. Individual in ear noise levels in 5 dB increments using IEC 60268 - 1:1985 noise Device / Trial Side of head IEC 60268 - 1:1985 (dB FS) - 35 - 30 - 25 - 20 - 15 - 10 DFE Correct individual in ear noise levels (dBA) 1/A Left 61.4 66.1 71.0 72.4 72.4 72.3 Right 61.4 66.2 71.1 72.4 72.4 72.4 1/B Left 70.9 72.3 72.3 72.2 72.3 72.3 Right 71.4 72.7 72.8 72.7 72.8 72.8 2/A Left 61.2 65.9 70.8 72.2 72.2 72.2 Right 61.9 66.6 71.5 72.8 72.8 72.9 2/B Left 70.9 72.3 72.3 72.4 72.3 72.3 Right 71.3 72.6 72.7 72.7 72.7 72.7 3/A Left 61.5 66.2 71.1 72.5 72.5 72.4 Right 61.7 66.5 71.3 72.7 72.7 72.6 3/B Left 71.2 72.6 72.6 72.6 72.5 72.6 Right 71.2 72.5 72.5 72.5 72.5 72.5 4/A Left 61.4 66.1 71.0 72.4 72.5 72.4 Right 61.6 66.3 71.2 72.6 72.7 72.7 4/B Left 71.2 72.6 72.6 72.6 72.6 72.6 Right 71.0 72.4 72.4 72.4 72.4 72.4
Share This Content
Share Link
Share on Social Media
Share by Email
Please login to share this Document by email.