Documentation
Completed
Ose_directory e-shot
3651 Views •Check Line II maintenance manual
4531 Views •Chemsplash Pro WD40 Test
4155 Views •ergonomics 2006
4488 Views •Ose_directory Suspension harness
3944 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
4855 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
4683 Views •VISOR Installation steps
4967 Views •Disinfection Products with effect on Corona Virus 2019 Ncov
4111 Views •Hearing protection 3M
3561 Views •Statistics for work in 2014
4201 Views •LOTO_GuideBook_Europe_English
4335 Views •Remote Area Lighting System
3103 Views •Isol8 - The Ultimate Absorbent for Spills
3090 Views •Work Magazine - November 2012
3444 Views •KEE_DOME_MINI
3385 Views •TDS Speedglas 9100
3602 Views •The Pocket Book of Lean Visuals
3623 Views •Instructional videos Sign holder
2887 Views •PREMARK installation manual
3738 Views •D-S CSR Handbook
19794 Views •Find glove size - size guide for gloves
12785 Views •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
8427 Views •3M jupiter manual
8323 Views •83735-00000A Safety Data Sheet
8249 Views •D S 70th Us brochure
7420 Views •9100 Manual
7275 Views •Explanation of the new EN ISO 374 standard chemicals
6535 Views •LA600 UI A3 26 LANGUAGES 22 08 2019 598
6460 Views •EN 388 new labels explanation
6399 Views •Fall Protection flyer
6332 Views •How to calibrate a 3M Jupiter air flow unit
5980 Views •3M TR 300 PAPR training video
5639 Views •TR-300 User manual
5250 Views •GuardianChemicalReport
5177 Views •Selection Guide respirator
4969 Views •VISOR Installation steps
4967 Views •VARMEX 2000 Benefits
4966 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
4855 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
4683 Views •T4x-Datasheet-British-English
Commenting is not enabled on this course.
3. Gases and ranges Gas Range Resolution Oxygen (O 2 ) 0-30% vol. 0.1% vol. Oxygen (O 2 ) Long Life 0-25% vol 0.1% vol Flammable 0-100% LEL 1% LEL Hydrogen sulphide (H 2 S) 0-100ppm 1ppm Carbon monoxide (CO) 0-1000ppm 1ppm Product variants and options Gas Sensor Options Configurations 2 gas 3 gas 4 gas New New Oxygen (O 2 ) Oxygen (O 2 ) Long Life Flammable MPS TM Flammable Pellistor Hydrogen sulphide (H 2 S) Carbon monoxide (CO) Carbon monoxide (CO) - H 2 immune
2. T4x Features TWA resume function Unique this innovative feature ensures toxic gas exposure is calculated accurately over an entire shift, even if switched off for a break or during travel to another site. Battery life T4x: 35+ hours battery (double the battery life of our original T4) allows multiple or longer shifts to be worked between recharging. Backlit display Large, clear display with backlight and option to flip the screen 180° for easy viewing whilst worn. Rugged design With a thick anti-shock rubber casing and drop tested to 4 metres on concrete, provides dependable operation under the most demanding use. Water & dust resistant to IP65 & IP67 Provides protection in the harshest environments. Dedicated sensors One sensor for every gas ensures effective, fast and reliable detection. Positive safety indicator A simple ‘traffic light’ status indicator which, at a glance, provides visual assurance of operational and compliance status to both users and supervisors. Green light - Working safely Red light - Attention required Intrinsically safe T4x: ATEX Type 1 (Zone 0) approved and UL Class 1 Division 1 allows for uninterrupted working in the most demanding environments. Multiple alarms Audible 95dB alarm, bright red/blue LED’s and vibrating alerts provide effective warning to gas hazards. Easy operation Large single button and intuitive menu system minimise training and allow easy operation whilst wearing gloves. T4x helps ensure compliance across site by eliminating the need to ensure each device is calibrated for the relevant flammable gas as it accurately detects more than 15 flammable gases, in any mix, at once, while being Type 1. Being poison resistant and with battery life doubled, operators are more likely to never be without a device. T4x reduces the 5 year total cost of ownership by over 25% and saves 12g of lead per detector which makes it easier to recycle at the end of its life, and better for the planet.
1. Specification Size 135 x 80 x 35mm (5.3 x 3.1 x 1.4in) Weight 282g (9.9oz) Durability Drop tested 4m onto concrete Alarms Audible Vibrating Visible 95dB Integrated Bright red & blue LED’s Display Front mounted, backlit, 180° flip for easy viewing while worn Logging Data Events 130 hours of data at 10s intervals 3,500 Battery Rechargeable Li-ion Up to 35 hours run time with MPS TM sensor fitted; 5.5 hour recharge Environment Operating temp Humidity Ingress protection -20 to +55°C (-4°F to +131°F)* 10-95% RH @ 40°C non-condensing Independently tested to IP65 and IP67 Compliance EMC Directive 2014/30/EU Approvals T4x ATEX and UKCA: II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) IECEx : Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) UL USA and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety MED: Directive 2014/90/EU Accessories Included with Integrated alligator clip and tethering loop Bump/calibration plate Available separately Single unit cradle charger; 10 unit cradle charger; Vehicle charger Clip on dust filter plate I-Test automated bump test and calibration station Crowcon Connect Compatible? Ye s *Toxic and oxygen sensors are not rated for continuous operation above 50°C (122°F) T4x Personal 4 Gas Monitor Now with industry leading MPS TM flammable gas and Long-Life oxygen sensors.
4. www.crowcon.com Specification Size 135 x 80 x 35mm (5.3 x 3.1 x 1.4in) Weight 282g (9.9oz) Durability Drop tested 4m onto concrete Alarms Audible Vibrating Visible 95dB Integrated Bright red & blue LED’s Display Front mounted, backlit, 180° flip for easy viewing while worn Logging Data Events 130 hours of data at 10s intervals 3,500 Battery Rechargeable Li-ion Up to 35 hours run time with MPS TM sensor fitted; 5.5 hour recharge Environment Operating temp Humidity Ingress protection -20 to +55°C (-4°F to +131°F)* 10-95% RH @ 40°C non-condensing Independently tested to IP65 and IP67 Compliance EMC Directive 2014/30/EU Approvals T4x ATEX and UKCA: II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) IECEx : Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) UL USA and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety MED: Directive 2014/90/EU Accessories Included with Integrated alligator clip and tethering loop Bump/calibration plate Available separately Single unit cradle charger; 10 unit cradle charger; Vehicle charger Clip on dust filter plate I-Test automated bump test and calibration station Crowcon Connect Compatible? Ye s *Toxic and oxygen sensors are not rated for continuous operation above 50°C (122°F) © 2022 Crowcon Detection Instruments Ltd. Copyright to some photographs held separately. Crowcon reserves the right to change the design or specification of the product without notice. Disclaimer Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement Crowcon Detection Instruments Limited reserves the right to make product changes without notice. The products are routinely subject to a programme of testing which may result in some changes in the characteristics quoted. Technical information contained in this document or otherwise provided by Crowcon are based upon records, tests, or experience that the company believes to be reliable, but the accuracy, completeness, and representative nature of such information is not guaranteed. Many factors beyond Crowcon Detection Instruments’ control and uniquely within user’s knowledge and control can affect the use and performance of a Crowcon product in a particular application. As the products may be used by the client in circumstances beyond the knowledge and control of Crowcon Detection Instruments Limited, we cannot determine the relevance of these to an individual customer’s application. It is the clients’ sole responsibility to carry out the necessary tests to evaluate the usefulness of the products and review all applicable regulations and standards to ensure their safety of operation in a particular application.
Share This Content
Share Link
Share on Social Media
Share by Email
Please login to share this Document by email.