Documentation
Completed
Ose_directory e-shot
3705 Views •Check Line II maintenance manual
4601 Views •Chemsplash Pro WD40 Test
4204 Views •ergonomics 2006
4570 Views •Ose_directory Suspension harness
4004 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
4938 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
4747 Views •VISOR Installation steps
5028 Views •Disinfection Products with effect on Corona Virus 2019 Ncov
4171 Views •Hearing protection 3M
3613 Views •Statistics for work in 2014
4256 Views •LOTO_GuideBook_Europe_English
4407 Views •Remote Area Lighting System
3146 Views •Isol8 - The Ultimate Absorbent for Spills
3147 Views •Work Magazine - November 2012
3501 Views •KEE_DOME_MINI
3449 Views •TDS Speedglas 9100
3664 Views •The Pocket Book of Lean Visuals
3687 Views •Instructional videos Sign holder
2944 Views •PREMARK installation manual
3825 Views •D-S CSR Handbook
19902 Views •Find glove size - size guide for gloves
12893 Views •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
8824 Views •3M jupiter manual
8454 Views •83735-00000A Safety Data Sheet
8306 Views •D S 70th Us brochure
7563 Views •9100 Manual
7362 Views •Explanation of the new EN ISO 374 standard chemicals
6625 Views •LA600 UI A3 26 LANGUAGES 22 08 2019 598
6516 Views •EN 388 new labels explanation
6460 Views •Fall Protection flyer
6411 Views •How to calibrate a 3M Jupiter air flow unit
6036 Views •3M TR 300 PAPR training video
5741 Views •TR-300 User manual
5351 Views •GuardianChemicalReport
5262 Views •Selection Guide respirator
5046 Views •VARMEX 2000 Benefits
5030 Views •VISOR Installation steps
5028 Views •Buyer's Guide advertisement Health and Safety International - Europe's magazine for employee protection and personal protective equipment
4938 Views •Demonstration of Velcro strap for mounting / installing the gas detector in fall protection harness
4747 Views •TDS_BLS600next_FLAT_DISPOSABLE
Commenting is not enabled on this course.
3. BLS 600 SERIES THREE-FLAP FLAT FILTERING FACEPIECES BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS600next-DISPOSABLE-FLAT-EN BLS filtering facepieces are: • Certified according to European Regulation 2016/425 (Personal Protective Equipments) • Certified as PPE of III category, in presumption of conformity to harmonized standard EN 149:2001+A1:2009 • Certified and controlled according to Annex D by Italcert S.r. l. (Notified Body n°0426) • CE marked BLS management system is ISO 9001 certified. P 3/3 BLS declines any responsibility, direct or indirect, from any misuse of both devices and instructions. User is responsible for the determ nation of product compliance with the intended use. AVAILABLE MODELS CERTIFICATIONS DONNING INSTRUCTIONS IMPORTANT CHECK FIT Put your hands on the mask and exhale sharply (unvalved mask); inhale sharply (valved mask). If you perceive there is air lea kage between the mask and your face you need to readjust the nosebri dge and the elastics. Repeate the adjustment until you achieve a proper fit. NOTE: it is unlikely to achieve a proper fit in case of people w ith beard BLS 670 Size M/L - Size S BLS 680 Size M/L - Size S
2. BLS 600 SERIES THREE-FLAP FLAT FILTERING FACEPIECES BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS600next-DISPOSABLE-FLAT-EN P 2/3 MATERIALS ELASTICS Polyester (PES) and synthetic rubber NOSE CLIP Polypropylene (PP) reinforced with heat-treated metal VALVE Polypropylene (PP); synthetic rubber GASKET Polyethylene foam (PE) FILTERING MATERIAL Polypropylene (PP) All components in direct contact with user’s face are LATEX FRE E BLS 600next filtering facepieces are Made in Europe, just as all of their components. PRODUCT CODE SIZE CLASS of PROTECTION NPF SINGLE PACK VALVE ELASTICS GASKET BLS 670next 8101026 S FFP2 NR D 12*TLV Rubber BLS 670next 8101022 M/L FFP2 NR D 12*TLV Rubber BLS 680next 8101028 S FFP2 NR D 12*TLV Rubber BLS 680next 8101027 M/L FFP2 NR D 12*TLV Rubber (NR) Non-reusable, maximum 8 hours (R) Reusable (TLV) Threshold Limit Value (NPF) Nominal protective factor (D) Product passed clogging test with Dolomite dust, simulates high concentration of solid particles TECHNICAL DATA PRODUCT CODE SIZE WEIGHT (g) Q.TY/BOX Q.TY/CARTON CARTON WEIGHT (Kg) Q.TY/PALLET BLS 670next 8101026 S 12 16 96 2.2 kg 3072 BLS 670next 8101022 M/L 12 16 96 2.2 kg 3072 BLS 680next 8101028 S 16 10 60 2.0 kg 1920 BLS 680next 8101027 M/L 16 10 60 2.0 Kg 1920 TRANSPORT FIELD OF USE Protection against dusts/fumes/aerosols of average toxicity particles in concentrations up to 12 x TLV (NPF) . Ex. constructions, cement manufacturing, foundries, grinding, sanding, dust painting, fiberglass cutting, wood (not hard wood), food industry. In addi - tion, 670next being an FFP2NRD without valve is the appropriate solution to reduce the possibility of contagion from virus/bacteria, so it can be used in medical applications as well.. LIMITATIONS OF USE Do not use this mask when: • Oxygen concentration is < 17% • The contaminants are unknown or are in concentrations exceeding the NPF • Gases/vapour are present STORAGE SHELF-LIFE 10 years TEMPERATURE +5°C/+40°C RELATIVE HUMIDITY <60%
1. BLS 600 SERIES THREE-FLAP FLAT FILTERING FACEPIECES BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS600next-DISPOSABLE-FLAT-EN P 1/3 BLS 600next filtering facepieces can be used to protect the user from solid and/or liquid nonvolatile particles up to 12* times the Threshold Limit Value (TLV-TWA). Elastics harness attached at four points, internal nose clip and seal ensure an excellent fit for most physiognomies. The dual size is designed to achieve the best fit-testing results. Thanks to the three-flap design, the device adapts perfectly to all facial movements, ensuring maximum protection and efficiency at all times. The folded lower flap allows easy opening of the facepie - ce without contaminating the inside. THREE-FLAP FLAT DESIGN Low respiratory resistance exhalation valve, which allows hot hu - mid exhaled air to escape more easily and ensures high comfort for the user, making the filtering facepiece suitable for hot humid work environments. AVAILABLE WITH EXHALATION VALVE INTERNAL NOSE CLIP The internal nose clip, placed between the layers of filter material, adapts optimally to the profile of the nose and eyes, guaranteeing good visibility and maximum compatibility with glasses. This series is available in two different sizes, M/L and S, to perfect - ly fit all face profiles. AVAILABLE IN TWO SIZES RUBBER ELASTICS The rubber elastics are made of hypoallergenic latex-free material. The addition of a supporting layer allows the elastics to adhere to the filter body without the use of exposed metal parts. The addition of an innovative inner core provides solidity to the filtering facepiece and high breathability, while maintaining low breathing resistance. RIGID INNER CORE Each mask is packed in an individually sealed PE pouch, to max - imize hygiene. It is also the best solution to carry the mask in a pocket, or have it available in vending machines. SINGLE PACKED The shape of the filtering facepiece guarantees a large filtering surface area, leaving the field of vision totally free. OPTIMAL VISUAL FIELD Nose gasket in soft polyethylene foam to increase comfort and fit. NOSE GASKET S -15% M/L
Share This Content
Share Link
Share on Social Media
Share by Email
Please login to share this Document by email.